ADSMEN1=0, ADSMS1=00, ADSMEN0=0, ADSMS0=00
General PWM Timer A/D Conversion Start Request Signal Monitoring Register
ADSMS0 | A/D Conversion Start Request Signal Monitor 0 Selection 0 (00): A/D conversion start request signal generated by the GTADTRA register during up-counting. 1 (01): A/D conversion start request signal generated by the GTADTRA register during down-counting. 2 (10): A/D conversion start request signal generated by the GTADTRB register during up-counting. 3 (11): A/D conversion start request signal generated by the GTADTRB register during down-counting. |
ADSMEN0 | A/D Conversion Start Request Signal Monitor 0 Output Enabling 0 (0): Output of A/D conversion start request signal monitor 0 is disabled. 1 (1): Output of A/D conversion start request signal monitor 0 is enabled. |
ADSMS1 | A/D Conversion Start Request Signal Monitor 1 Selection 0 (00): A/D conversion start request signal generated by the GTADTRA register during up-counting. 1 (01): A/D conversion start request signal generated by the GTADTRA register during down-counting. 2 (10): A/D conversion start request signal generated by the GTADTRB register during up-counting. 3 (11): A/D conversion start request signal generated by the GTADTRB register during down-counting. |
ADSMEN1 | A/D Conversion Start Request Signal Monitor 1 Output Enabling 0 (0): Output of A/D conversion start request signal monitor 1 is disabled. 1 (1): Output of A/D conversion start request signal monitor 1 is enabled. |